Water heater gas control valve: settings, flash codes and when it needs replacing
On a standard gas water heater, the box with the knob on the front is the gas control valve. It's the thermostat and the safety shutoff in one, and on many newer heaters its little status light tells you exactly what's wrong.
Updated October 26, 2026 · 6 min read · By the Heater Doctor team

Short answer
The gas control valve sets the water temperature, lights the pilot and shuts off the gas if something is unsafe. On A. O. Smith heaters, "Hot" is about 120°F and "Low" or vacation is about 55°F. On models with a Honeywell valve, a status light blinks a code: one flash is normal, two means low thermopile voltage, and four (overheat), five (sensor), seven (internal failure) or eight (power-off failure) mean A. O. Smith's fix is replacing the valve. The valve isn't repaired, only replaced.
What the valve does
The gas control valve, often called the gas control valve/thermostat, controls the gas to both the pilot and the main burner. It reads the water temperature through a sensor in the tank and opens the burner when the water cools. On A. O. Smith's FVIR models with a Honeywell valve, it's powered by a thermopile that the pilot heats, which A. O. Smith says generates 750 to 900 millivolts with no load. There's no plug: no pilot, no power.
If the water gets too hot, the main burner and pilot shut off automatically.
The dial settings
A. O. Smith lists these settings for its gas control knob:
- Low (vacation): about 55°F
- Hot: about 120°F, its recommended setting
- A: about 128°F
- B: about 138°F
- C: about 147°F
- Very Hot: about 160°F
It warns that 140°F water can burn in under five seconds. For trips, Rheem suggests vacation mode for a week or so and pilot mode, which shuts the main burner off but keeps the pilot lit, for longer ones. See what temperature a water heater should be and how to turn off a water heater.
Reading the status light
A. O. Smith's service handbook for its Honeywell-valve models lists these codes. Each code repeats after a 3-second pause:
- Not lit: the control is off or the pilot is out. Relight following the label.
- Solid on: the pilot recently went out and the thermopile is cooling. Turn the knob off and wait 10 minutes before relighting; the valve won't allow a quicker retry.
- 1 flash: normal operation.
- 2 flashes: thermopile voltage low. Check the wiring; A. O. Smith says to replace the thermopile if it reads under 350 millivolts.
- 4 flashes: temperature exceeded, meaning the high-limit (ECO) tripped. Replace the valve.
- 5 flashes: sensor failure. Replace the valve.
- 7 flashes: internal control failure. Replace the valve.
- 8 flashes: power-off failure. If the pilot stays lit with the knob off, replace the valve.
After lighting, it can take up to 90 seconds of pilot flame before the light starts blinking. Other brands use different valves and codes, so check the label on your heater. If the pilot won't stay lit at all, see pilot light keeps going out; on older valves with a thermocouple, see our thermocouple guide.
Replace, don't repair
Every valve fault in A. O. Smith's handbook ends the same way: turn the knob off, turn the main gas supply off and replace the gas control valve/thermostat. The U.S. Consumer Product Safety Commission is even firmer about valves that have been underwater: they can't be salvaged and must be replaced, because silt and corrosion can stop them working and let gas leak (see water heater after a flood).
If you smell gas, A. O. Smith says to turn off the gas supply valve and call a professional rather than keep troubleshooting. See water heater smells like gas.
Valve or new heater?
A valve is a covered part under most tank warranties during the parts term, which is 6, 8 or 10 years on A. O. Smith's residential models, though labor isn't covered (see water heater warranty). On a heater near the end of its life, the cost of a valve plus labor often points to replacement instead. Check how old yours is.
Gas tanks are common where homes run on gas. About 69% of Caldwell, Idaho homes heat with gas, with Intermountain Gas holding the city franchise (see our Caldwell page), and in Marshfield, Massachusetts about 61% heat with gas (see our Marshfield page). Our gas water heater repair page covers valve replacements.
Rather have a plumber look at it?
Call and describe what's happening. We'll get a plumber out to diagnose and fix it.
Call for service(858) 465-8561Local pages mentioned
Related water heater services
Common questions
What does 4 flashes mean on a water heater gas valve?
On A. O. Smith heaters with a Honeywell valve, four flashes means the temperature limit (ECO) was exceeded. A. O. Smith's fix is replacing the gas control valve.
Can a water heater gas valve be repaired?
No. A. O. Smith's service steps call for replacing the gas control valve/thermostat, and the CPSC says valves that have been underwater must be replaced.
What temperature is Hot on a gas water heater dial?
On A. O. Smith's gas control knob, Hot is about 120°F. A is about 128°F, B 138°F, C 147°F and Very Hot 160°F.
Sources
- A. O. Smith, Service Handbook: Residential FVIR Gas Water Heaters (Honeywell gas control valve models)
- A. O. Smith, How to Turn a Water Heater On & Off
- Rheem, Summer Vacation Tips: Should You Turn Off Your Gas Water Heater?
- U.S. Consumer Product Safety Commission, Warning to Flood Victims: Replace All Gas Control Valves, Electric Circuit Breakers, GFCIs, and Fuses That Have Been Under Water
- A. O. Smith, Is Your Hot Water Not Getting Hot? Common Causes & What To Do
- A. O. Smith, Limited Warranty: Residential Type Water Heater for Installation in a Single Family Dwelling
General information only. Gas, electrical and pressure work can be dangerous; when in doubt, call a licensed professional.
Still stuck? Get a plumber out.
Call now for water heater repair or replacement.