A full tank water heater is heavy and top-heavy. In an earthquake an unsecured one can walk, tip and tear its gas and water lines loose. Seismic straps are cheap and simple, but only if they're the right kind in the right places. Here's what the code requires, which states insist on it, and how health officials say to install them.

Updated October 29, 2026 · 6 min read · By the Heater Doctor team

Tank water heater with an expansion tank and copper piping in a garage

Short answer

Where seismic bracing applies, the International Residential Code requires water heaters to be anchored or strapped in the upper one-third and the lower one-third of the tank, so two straps. The model code applies this in Seismic Design Categories D0, D1 and D2 (and townhouses in C). Utah's residential code requires it for all water heaters as a minimum, and A. O. Smith's manuals note that California requires bracing, anchoring or strapping. Washington's Department of Health recommends heavy-gauge metal straps at top and bottom, lagged into wall studs, rather than plumber's tape.

Why water heaters get strapped

A 50-gallon tank holds more than 400 pounds of water alone (water weighs about 8.3 pounds a gallon), sitting high on a narrow base. Washington's Department of Health says experts changed how water heaters are strapped after the 1989 Loma Prieta and 1994 Northridge earthquakes, because so many tanks burst through the single strap of plumber's tape that was common before.

There's a second reason: a standing water heater is an emergency water supply. The department notes that after a disaster you can draw fresh water from the drain valve with a garden hose and an open faucet, provided the tank stays upright, and that the electricity or gas should be off before you open the drain.

What the code requires

RuleWhere it appliesWhat it says
IRC P2801.8 (model code)Seismic Design Categories D0, D1, D2, and townhouses in CAnchor or strap in the upper and lower thirds, to resist a horizontal force equal to one-third of the heater's operating weight, or per the manufacturer
Utah P2801.8 (state amendment)All water heaters, as a minimumAnchor or strap to resist earthquake movement, at points within the upper and lower thirds
CaliforniaStatewideBracing, anchoring or strapping required, per the notice in A. O. Smith's manuals

A. O. Smith's manuals say that if your area is prone to earthquakes, use special straps as required by local building codes, and that other locations may have requirements similar to California's, so check with local and state authorities. Whether your house falls in one depends on its location and the code edition your jurisdiction adopted; your building department can tell you.

How many straps, and where

  • Two. The code wording, upper one-third and lower one-third, means one strap near the top of the tank and one near the bottom. Washington's Department of Health likewise says to secure both the top and the bottom, rather than just the top or the middle.
  • Clear of the controls. Position the lower strap so it doesn't cover the gas control or the electric access panels, so the heater can still be serviced.
  • Tight to the wall. The department says there should be very little space between the tank and the wall so it can't tip backwards; if the gap is more than 1 or 2 inches, attach a wooden block to the wall with long lag screws.

How to install water heater straps

These steps follow Washington's Department of Health guidance. A commercial strapping kit, sold in hardware stores near the water heaters, includes the strapping, lag screws, washers, spacers and tension bolts.

  1. Find the studs behind the heater, or add a wood block if the tank sits more than an inch or two from the wall.
  2. Use heavy-gauge metal strapping, not plumber's tape.
  3. Wrap each strap 1½ times around the tank. Start at the back, bring it to the front, then take it back to the wall.
  4. Fasten to the studs or block with several 1/4-inch by 3-inch or longer lag screws and oversized washers. Into concrete, use 1/4-inch expansion bolts instead.
  5. Repeat for the second strap in the lower third, then tension both so the tank can't move.

If your kit's instructions differ, follow them, since the code also allows strapping per the appliance manufacturer's recommendations.

Don't forget the connections

Washington's Department of Health also recommends replacing rigid copper and metal piping at the heater with flexible gas and water connectors, so the lines can move a little without breaking. A. O. Smith's gas manual calls for a new CSA-approved gas supply line. Gas connections are a job for a qualified installer (see water heater shut-off valve for where to shut things off in an emergency).

Strapping when you replace a heater

A replacement is the easiest time to add or upgrade straps, and in places that require them the new install has to meet the code. Ask your installer whether straps are included. Replacing a water heater may also need a permit and inspection where you live (see do you need a permit to replace a water heater). A heater in a garage may need other protections too, such as a drain pan in some locations (see water heater drain pan) and an expansion tank if your system needs one (see water heater expansion tank).

Utah homes

Because Utah's amendment applies to all water heaters, homes in Salt Lake City and the other Utah towns we serve should have two straps on every tank. If yours has none, one strap, or plumber's tape, it's worth fixing.

Rather have a plumber look at it?

Call and describe what's happening. We'll get a plumber out to diagnose and fix it.

Call for service(858) 465-8561

Local pages mentioned

Questions

Common questions

Do water heaters need earthquake straps?

Where the code requires seismic bracing, yes: the IRC requires it in Seismic Design Categories D0 to D2, Utah requires it for all water heaters, and California requires it statewide. Elsewhere, ask your building department.

How many earthquake straps does a water heater need?

Two. The code places them within the upper one-third and the lower one-third of the tank.

What states require water heater straps?

California and Utah require them statewide. Under the model IRC, strapping applies in Seismic Design Categories D0, D1 and D2 wherever that code is adopted, so check locally.

Can I use plumber's tape to strap a water heater?

Washington's Department of Health recommends heavy-gauge metal strapping instead, because many tanks burst through plumber's tape in the 1989 and 1994 California earthquakes.

How do you install earthquake straps on a water heater?

Wrap heavy-gauge metal strapping 1½ times around the tank at the top and bottom thirds, then lag it into wall studs with 1/4-inch by 3-inch or longer screws and oversized washers.